Startup

WARNING

INJECTION HAZARD

The system pressure must be manually

relieved to prevent the system from

starting or spraying accidentally. Fluid

under high pressure can be injected through the

skin and cause serious injury. To reduce the risk of

an injury from injection, splashing fluid, or moving

parts, follow the

Pressure Relief Procedure

whenever you:
D are instructed to relieve the pressure,
D stop spraying,
D check or service any of the system equipment,
D or install or clean the spray tip.

Pressure Relief Procedure

1. Engage the gun safety latch.
2. Turn the ON/OFF switch to OFF.
3. Unplug the power supply cord.
4. Disengage the gun safety latch. Hold a metal part

of the gun firmly to a grounded metal pail. Trigger

the gun to relieve pressure.

5. Engage the gun safety latch.
6. Open the pressure drain valve. Leave the pressure

drain valve open until you are ready to spray

again.

If you suspect that the spray tip or hose is completely

clogged, or that pressure has not been fully relieved

after following the steps above, VERY SLOWLY loos-

en the tip guard retaining nut or hose end coupling to

relieve pressure gradually, then loosen completely.

Now clear the tip or hose obstruction.

Startup Procedure

Use this procedure each time you start the sprayer to

help ensure the sprayer is ready to operate and that

you start it safely.

NOTE: If this is a first-time startup, flush the sprayer.

See page 12.

NOTE: Refer to Fig. 2 and the other figures referenced

in the text as you start the sprayer.

1.

Open the pressure drain valve (42). See Fig. 8.

2.

Don’t install the spray tip until the pump is

primed!

3.

Put the suction tube (32) into the paint. If you

are pumping from a pail, push the drain hose (33)

down below the top of the pail to avoid splashing

paint when the drain is opened.

Open or drain, position

Fig. 8

1

1

42

04648

4.

Turn the pressure knob (64) to the minimum

setting.

5.

Disengage the gun trigger safety. See Fig. 4,

page 7.

CAUTION

Do not run the sprayer dry for more than 30 seconds

to avoid damaging the pump packings.

6.

To prime the pump, turn the sprayer switch (52)

on.

Slowly increase the pressure until the sprayer

starts. When fluid comes from the pressure drain

valve, close the valve.

Advertising