Hoshizaki KM-901MWH User Manual

Page 22

Advertising
background image

22

(3) Freeze Cycle

LED 1 is on. Comp and FMR remain energized, PM, FM, and LLV energize. HGV
and WV de-energize. For the first 5 minutes, CB will not accept a signal from F/S.
This minimum 5-minute freeze time is short cycle protection for Comp. At the end of
5 minutes, F/S assumes control. As ice builds on the evaporator, the water level in
the tank lowers. The freeze cycle continues until F/S opens and terminates the cycle.
There is a 15 second delay before CB acknowledges an open F/S.

(4) Pump-Out Cycle

LEDs 1, 3, and 2 are on. LED 4 is on when S4 dip switch 3 & 4 are set to 3 off and
4 on. Comp and FMR remain energized, HGV energizes, WV energizes if S4 dip
switch 3 off and 4 on. LLV and FM de-energize. PM stops for 2 seconds then
reverses, taking water from the bottom of the tank and forcing pressure against the
check valve seat allowing water to go through the check valve and down the drain.
At the same time, water flows through the small tube to power flush F/S. When the
pump-out timer expires, the pump-out is complete.

The first pump-out occurs after the 11th freeze cycle, then every 10th cycle
thereafter. The pump-out frequency control is factory set, and generally no
adjustment is required. However, where water quality is bad and the icemaker needs
a pump-out more often, the pump-out frequency can be adjusted. The pump-out
frequency control (S4 dip switch 5 & 6) can be set to have a pump-out occur every
cycle, or every 2, 5, or 10 cycles. Timing of the first pump-out is dependent on S4
dip switch 5 & 6 settings. See the table below. For details, see "II.C.3.d) Pump-Out
Frequency Control (S4 dip switch 5 & 6)."

"G" Control Board Settings

S4 Dip Switch Setting

Pump-Out

Frequency

1st Pump-Out

No. 5

No. 6

OFF

OFF

Every cycle

After 2nd freeze cycle

ON

OFF

Every 2 cycles

After 3rd freeze cycle

OFF

ON

Every 5 cycles

After 6th freeze cycle

ON

ON

Every 10 cycles

After 11th freeze cycle

(5) Harvest Cycle

Same as the initial harvest cycle. See "II.B.1.b)(2) Initial Harvest Cycle."
Note: Unit continues to cycle until MBC is satisfied or power is turned off. The unit

always restarts at the 1-minute fill cycle.

Advertising
This manual is related to the following products: