Km-901mwh (water-cooled) – Hoshizaki KM-901MWH User Manual

Page 47

Advertising
background image

47

Note:
1. Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold

should be used for reference only.

2. We reserve the right to make changes in specifications and design without prior

notice.

2. KM-901MWH (water-cooled)

70/21

912

414

889

403

849

385

80/27

895

406

860

390

815

370

90/32

889

403

835

379

791

359

lbs./day kg./day

100/38

878

398

825

374

751

341

70/21
80/27
90/32

watts

100/38

70/21

876

3.32

1013

3.84

1530

5.79

80/27

981

3.71

1194

4.52

1893

7.17

90/32

1013

3.84

1344

5.09

1977

7.48

gal./day m

3

/day

100/38

1360

5.15

1493

5.65

2559

9.69

70/21
80/27
90/32

min.

100/38

70/21
80/27

90/32

min.

100/38

70/21

227

16.0

230

16.1

240

16.9

80/27

229

16.1

233

16.4

247

17.4

90/32

230

16.1

236

16.6

249

17.5

PSIG kg/cm

2

G

100/38

234

16.4

239

16.8

260

18.3

70/21

33

2.3

34

2.4

38

2.6

80/27

34

2.4

36

2.5

40

2.8

90/32

34

2.4

37

2.6

41

2.9

PSIG kg/cm

2

G

100/38

36

2.5

38

2.7

45

3.2

13,500 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

TOTAL HEAT OF REJECTION FROM COMPRESSOR

2,100 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

WATER FLOW FOR CONDENSER

100 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]

PRESSURE DROP OF COOLING WATER LINE

less than 10 PSIG

19

19
19

3.0

4.1

3.4

3.8
3.4

18

20

APPROXIMATE ICE

PRODUCTION PER 24 HR.

APPROXIMATE ELECTRIC

CONSUMPTION

APPROXIMATE WATER

CONSUMPTION PER 24 HR.

FREEZING CYCLE TIME

WATER TEMP. (ºF/ºC)

AMBIENT TEMP.

(ºF/ºC)

50/10

70/21

90/32

1505

1506
1541
1570
1574

1480
1500
1506

20
21
21
22

1527
1553
1586
1600

19
19

20

HARVEST CYCLE TIME

3.6
3.3

3.8

2.9

3.1

3.9

2.7

TOTAL HEAT OF REJECTION FROM CONDENSER

SUCTION PRESSURE

HEAD PRESSURE

ENG.F-011.1.0205

Advertising
This manual is related to the following products: