Hoshizaki KM-901MWH User Manual

Page 61

Advertising
background image

61

Problem

Possible Cause

Remedy

[1] The icemaker will not

start. (continued)

h) Transformer

1. Coil winding open or

shorted.

1. Replace.

i) Wiring to Control Board 1. Loose connections or

open.

1. Check for continuity and

replace.

j) Interlock Switch

(Cleaning Valve)

1. Open position.

1. Move to closed position.

2. Bad contacts.

2. Check for continuity and

replace.

k) Mechanical Bin Control 1. Movement restricted.

1. Check and free.

2. Defective

2. See "IV.C.2. Mechanical

Bin Control Check and
Cleaning."

l) Thermistor

1. Leads shorted or open

and high temperature
or harvest backup
timer safety operates
(1 beep or 2 beep
alarm).

1. See "IV.E. Thermistor

Check."

m)Hot Gas Valve

1. Continues to open

in freeze cycle and
freeze timer safety
operates (3 beep
alarm).

1. Check for hot gas valve

stuck open and replace.

n) Inlet Water Valve

1. Mesh filter or orifice

gets clogged and
water supply cycle
does not finish.

1. Clean.

2. Coil winding open.

2. Replace.

3. Wiring to inlet water

valve.

3. Check for loose connection

or open, and replace.

o) Float Switch

1. Bad contacts.

1. Check for continuity and

replace.

2. Defective switch.

2. Clean or replace. See "IV.

D. Float Switch Check and
Cleaning."

p) Control Board

1. Defective or in alarm. 1. See "IV.B. Control Board

Check."

[2] Fill cycle will not

terminate.

a) Water Supply

1. Water supply off or

pressure too low.

1. Check and get

recommended pressure.

b) Float Switch

1. Connector

disconnected.

1. Reconnect.

2. Float does not move

freely or switch
defective switch.

2. Clean or replace. See "IV.

D. Float Switch Check and
Cleaning."

c) Control Board

1. Defective.

1. See "IV.B. Control Board

Check."

Advertising