67

Problem

Possible Cause

Remedy

[2] Cloudy or irregular

cubes.

a) Evaporator

1. Frozen up.

1. See chart 2.

2. Scaled up.

2. Clean

3. Damaged.

3. Replace.

b) Water System

1. Water supply line too

small; requires 3/8"
OD line dedicated per
machine.

1. Increase water line size.

2. Water filter clogged or

flow rate too small.

2. Replace filter or install a

higher flow rate filter.

3. High hardness or

contains impurities.

3. Install a water softener or

filter.

c) Spray Guide

1. Dirty.

1. Clean.

5. Other

Problem

Possible Cause

Remedy

[1] Icemaker will not stop

when bin is filled with
ice.

a) Thermostatic Bin

Control

1. Set too cold.

1. See "IV.C.1. Thermostatic

Bin Control Check."

2. Defective.

2. Replace.

b) Mechanical Bin Control 1. Movement restricted.

1. Check and free.

2. Loose connection.

2. Check and reconnect.

3. Defective

3. See "IV.C.2. Mechanical

Bin Control Check and
Cleaning."

c) Control Board ("G"

control board with
mechanical bin control)

1. Defective.

1. See "IV.B. Control Board

Check."

[2] Abnormal noise.

a) Pump Motor

1. Bearings worn out.

1. Replace.

b) Fan Motor (except

water-cooled model)

1. Bearings worn out.

1. Replace.

2. Fan blade deformed.

2. Replace.

3. Fan blade does not

move freely.

3. Replace.

c) Compressor

1. Bearings worn out or

cylinder valve broken.

1. Replace.

2. Mounting pad out of

position.

2. Reinstall.

d) Refrigerant Lines

1. Rub or touch other

lines or surfaces.

1. Reposition.

[3] Ice in storage bin

often melts.

a) Drain Line(s)

1. Plugged.

1. Clean.

b) Icemaker and Bin

1. Drains not run

separately.

1. Separate the drain lines.

c) Ice Cube Guide

1. Out of position.

Circulated water falls
into bin.

1. Place in position.

Advertising