Recognizing drive failure – HP 5300 User Manual

Page 119

Advertising
background image

Hard Drive Installation and Replacement

E-2

HP Smart Array 5300 Controller User Guide

HP CONFIDENTIAL

Writer: Jennifer Hayward File Name: o-appe hard drive installation and replacement

Codename: SilverHammer Part Number: 135606-005 Last Saved On: 10/8/02 11:22 AM

• RAID 1+0 configurations can tolerate multiple drive failures as long as no failed

drives are mirrored to one another.

• RAID 5 configurations can tolerate one drive failure.
• RAID ADG configurations can tolerate simultaneous failure of two drives.

If more hard drives fail than the fault-tolerance method allows, fault tolerance is
compromised and the logical drive fails. In this case, all requests from the operating
system will be rejected with unrecoverable errors. The “Compromised Fault
Tolerance”
section discusses possible ways to recover from this situation.

Recognizing Drive Failure

The LEDs on the front of each hard drive are visible through the front of the server or
external storage unit. When a drive is configured as a part of an array and attached to
a powered-up controller, the status of the drive can be determined from the
illumination pattern of these LEDs.

Table E-1 describes the meaning of the various LED combinations.

1

2

3

Figure E-1: Hard drive status LED indicators