POST Error Messages

G-8

HP Smart Array 5300 Controller User Guide

HP CONFIDENTIAL

Writer: Jennifer Hayward File Name: q-appg POST messages

Codename: SilverHammer Part Number: 135606-005 Last Saved On: 10/8/02 11:26 AM

Table G-1: POST Error Messages

continued

Message

Description

Meaning and Recommended Action

1785

Slot 1 Drive Array not Configured (may
be followed by one of the following
messages):

(1) No drives detected

(2) Drive positions appear to have
changed. Run the Array Diagnostics
Utility (ADU) if previous positions are
unknown, then turn system power OFF
and move drives to their original
positions.

(3) Configuration information indicates
drive positions beyond the capability of
this controller. This may be due to
drive movement from a controller that
supports more drives than the current
controller.

(4) Configuration information indicates
drives were configured on a controller
with a newer firmware version.

(1) Turn off the system and check SCSI
cable connections to be sure that drives are
attached properly.

(2) Run the Array Diagnostics Utility (ADU)
if previous positions are unknown. Then
power the system down and move drives to
their original positions.

(3) To avoid data loss, power the system
down and reattach drives to the original
controller.

(4) To avoid data loss, reattach drives to
the original controller or upgrade the
controller firmware to the version on the
original controller using the Options
ROMPaq utility.

Press the F1 key to resume.