D. mantel and wall projections – Hearth and Home Technologies 6000GL-IPILP-S User Manual

Page 20

Advertising
background image

Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08

20

D. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing or fi nishing material closer than
the minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc).

Combustible Mantels

Combustible Mantel Legs or Wall Projections

MEASUREMENTS FROM

TOP EDGE OF THE OPENING

5

10

11

12

2-1/2

13

14

15

16

17

18

19

32

TO CEILING

9

10

11

12

8

7

6

5

4

3

25

18

A

B

INTERIOR WALL

TOP VIEW

MANTEL LEG OR WALL PROJECTIONS

FIREPLACE OPENING

Note: All measurements in inches.

If

A

minimum is ____, then

B

maximum is_____.

A

Inches

2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16

Millimeters

62

87

113

138

164

189

B

Inches

1

2

3

4

5

Millimeters

25

51

76

102

127

Note: Measurement is taken from top of the
opening, NOT the top of the fi replace.

Figure 5.4 Clearances to Mantel Legs or Wall Projections

(Acceptable on both sides of opening.)

Figure 5.3 Minimum Vertical and Maximum Horizontal

Dimensions of Combustibles

Advertising
This manual is related to the following products: