Warning, Top vent - horizontal termination, E. vent diagrams – Hearth and Home Technologies 6000GL-IPILP-S User Manual

Page 24

Advertising
background image

Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08

24

INSTALLED

HORIZONTALLY

H

1

H

2

V

1

H

1

V

1

Figure 7.3

Figure 7.4

Top Vent - Horizontal Termination

Top Vent - Horizontal Termination

One Elbow

Two Elbows

Note: For corner installations: A 6 inch (152
mm) section of straight pipe may need to
be attached to the appliance before a 90º

elbow, to allow the vent pipe to clear the top
standoffs.

Note: For corner installations: A 6 inch
(152 mm) section of straight pipe may
need to be attached to the appliance
before a 90º

elbow, to allow the vent

pipe to clear the top standoffs.

V

1

Minimum

H

1

Maximum

Elbow only

2 ft

610 mm

1 ft.

305 mm

3 ft.

914 mm

2 ft.

610 mm

6 ft.

1.8 m

3 ft.

914 mm

11 ft.

3.4 m

4 ft.

1.2 m

20 ft.

6.1 m

V

1

+ H

1

= 40 ft. (12.2 m) Maximum

H

1

= 20 ft. (6.1 m) Maximum

Fire Risk. Explosion Risk.

Do NOT pack insulation or other combustibles
between ceiling fi restops.

• ALWAYS maintain specifi ed clearances around

venting and fi restop systems.

• Install wall shield and ceiling fi restops as speci-

fi ed.

Failure to keep insulation or other material away
from vent pipe may cause fi re.

Example: DVP pipe 3 ft. min. vertical = 11 ft. max. horizontal

SLP pipe 7 ft. min. vertical = 11 ft. max. horizontal

V

1

Minimum

H

1

+ H

2

Maximum

Elbow only

1 ft.

305 mm

6 in.

152 mm

2 ft.

610 mm

1 ft.

305 mm

2 ft.

610 mm

2 ft.

610 mm

4 ft.

1.2 m

3 ft.

914 mm

9 ft.

2.7 m

4 ft.

1.2 m

18 ft.

5.5 m

5 ft.

1.5 m

20 ft.

6.1 m

V

1

+ H

1

+ H

2

= 40 ft. (12.2 m) Maximum

H

1

+ H

2

= 20 ft. (6.1 m) Maximum

Fire Risk.
• When using DVP-HRC-SS and DVP-HRC-ZC-

SS termination caps on top vented fi replaces, a
6 inch minimum vertical vent section is required
before installing fi rst elbow.

WARNING

WARNING

E. Vent Diagrams

Note: The 6000 series fi replaces can adapt to SLP series vent

pipe, if desired.

When venting off the top of the unit, use a DVP-2SL adapter and a
minimum 48 inch vertical section of SLP series vent pipe.

A DVP-SLP24 adapter may also be used with a 24 inch vertical
section of SLP series vent pipe.

After the 48 inch vertical section, the venting table rules must be
followed. The fi rst 48 inch vertical section is NOT counted as part
of the vertical components in the table. It is still counted as part of
the overall maximum run. All venting table rules for the vent run
must still be followed.