Finishing

A. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materi-
als (i.e., steel studs, concrete board, etc.) Failure to comply
could cause fi re.

Figure 13.2 Combustible Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

Figure 13.1 Minimum Vertical and Maximum Horizontal

Dimensions of Combustibles

Combustible Mantels

Combustible Mantel Legs or Wall Projections

MEASUREMENTS FROM

TOP EDGE OF THE OPENING

5

10

11

12

2-1/2

13

14

15

16

17

18

19

32

TO CEILING

9

10

11

12

8

7

6

5

4

3

25

18

A

B

INTERIOR WALL

TOP VIEW

MANTEL LEG OR WALL PROJECTIONS

FIREPLACE OPENING

Note: All
measurements
in inches.

If

A

minimum is ____, then

B

maximum is_____.

A

Inches

2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16

Millimeters

62

87

113

138

164

189

B

Inches

1

2

3

4

5

Millimeters

25

51

76

102

127

Note: Measurement is taken from top of the opening,
NOT the top of the fi replace.

B. Facing Material

• Metal front faces may be covered with non-combustible

materials only.

• Facing and/or fi nishing materials must not interfere with

air fl ow through louvers, operation of louvers or doors,
or access for service.

• Facing and/or fi nishing materials must never overhang

into the glass opening.

• Observe all clearances when applying combustible

materials.

• Seal joints between the fi nished wall and appliance top

and sides using a 300 ºF minimum sealant. Refer to
Figure 13.3.

WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.

Figure 13.3 Noncombustible Facing Diagram

41 in.

39-3/8 in.

NON-COMBUSTIBLE ZONE (Shaded areas)