D. electrical service and repair – Hearth and Home Technologies 6000GL-IPILP-S User Manual

Page 48

Advertising
background image

Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08

48

D. Electrical Service and Repair

WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.

Figure 12.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram

WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.

Note: Appliance will not operate
unless properly grounded.

PLUG-IN

3V TRANSFORMER

ON/OFF

WALL SWITCH

IGNITION

MODULE

(3V)

VALVE

NEUTRAL

GROUND

LOW VOLTAGE

SEE NOTE 1

REMOTE

CONTROL

HOT

PLUG-IN

REMOTE

JUMPER WIRE

ORG

GR

N

BRN

BRN

RED

BLK

INTERMITTENT

PILOT IGNITOR

ORG

WHT

IGNITION MODULE 3 VAC

TRANSFORMER

VALVE

3 VAC

THERMOSTAT

WIRE

ASSEMBLY

BLACK WIRE CAN BE

PLUGGED INTO ANY

OF #1 - #5 LOCATIONS

ON THE HOT SIDE

WHITE WIRE CAN BE

PLUGGED INTO ANY

OF#1 - #5 LOCATIONS

ON THE NEUTRAL SIDE

GROUND TO

FIREPLACE

CHASSIS*

Advertising
This manual is related to the following products: