C. Check Firebrick

Frequency: After each ash removal
By: Homeowner

D. Inspect Grate

Frequency: After each ash removal
By: Homeowner

Inspect grate for:

• Warping or sagging 1-1/2 in. (38 mm) or more
• Broken

welds

• Burn-through of grate bars
For safe operation, replace only with an approved grate
from Hearth & Homes Technologies Inc.

WARNING! Risk of Fire! Inspect fi rebrick. Crumbling,
deteriorated fi rebrick can allow overheating of surround-
ing materials.

Expansion and contraction will cause minor cracking of
the fi rebrick. This is normal. The fi rebrick will require peri-
odic replacement depending on use.

• Replace

broken

fi rebrick.

E. Glass Cleaning

Frequency: As desired
By: Homeowner

Clean glass with a non-abrasive commercially available
cleaner or ashes:

• Light

deposits

- Use household glass cleaner

• Heavy

deposits

- Use wood ash on damp cloth or,
- Use

commercial

fi replace glass cleaner (consult with

your dealer)

CAUTION! Handle glass assembly with care. Glass is
breakable.
• Avoid striking, scratching or slamming glass
• Avoid abrasive cleaners
DO NOT clean glass while it is hot

Heatilator • SC60 • 32838 Rev X • 10/08