Tct375 terra cotta cap – Hearth and Home Technologies HEATILATOR SC60 User Manual

Page 34

Advertising
background image

34

Heatilator • SC60 • 32838 Rev X • 10/08

Chimney

Pipe

Chase Top

Termination Cap

Chase

3 in. (76 mm)

Maximum

top of chase to

top of

chimney section

Collar

2 in. (51 mm)

Minimum Height

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm).

Place waterproof
sealer under each
flange of the termina-
tion cap and on top of
each screw to help
prevent leaks.

Figure 9.7 Installing a TS345/TS345P Square Termination Cap

• TS345/TS345P Square Termination Cap

Chimney

Pipe

Chase Top

Termination Cap

Chase

Collar

2 in. (51 mm)

Minimum Height

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)

Place waterproof
sealer under each
flange of the termina-
tion cap and on top of
each screw to help
prevent leaks.

The last section of pipe
must stop between 2 in.
(51 mm) above top of
chase and 7 in. (178
mm) below top of chase

2 in. (51 mm)

7 in. (178 mm)

Figure 9.8 Installing a TCT375 Terra Cotta Cap

• TCT375 Terra Cotta Cap

Advertising