D. install chimney air kit, E. install ceiling firestops – Hearth and Home Technologies HEATILATOR SC60 User Manual

Page 27

Advertising
background image

27

Figure 8.4 Assembling Chimney Sections

ROOM ABOVE (non-insulated ceiling)

ATTIC ABOVE (insulated ceiling)

B

A

Ceilng firestop from

bottom

Ceiling firestop from

top

Note:

Use same dimensional lumber for framing

ceiling firestop and joists.

Figure 8.5 Installing the Ceiling Firestop

• Support the pipe during construction and check to be

sure inadvertent loading has not dislodged the chimney
section from the fi replace or at any chimney joint.

• Attach a straight chimney section or an offset to the top

of the fi replace.

• Place

inner

fl ue to the inside of the chimney section below

it. Place the outer casing outside the outer casing of the
chimney section below it. Refer to Figure 8.4.

NOTICE:

Chimney sections cannot be disassembled

once locked together. Plan ahead!

• Lock chimney sections and/or offsets/returns together by

pushing downward until the top section meets the stop
bead on the lower section.

• Pull on the top section to make sure it is fully engaged

and will not separate.

• You may use #6 or #8 sheet metal screws no longer than

1/2 in. (13 mm) to fasten chimney sections together. Do
NOT penetrate inner fl ue.

WARNING! Risk of Fire! You MUST use screws (pro-
vided) to fasten offset/returns to chimney sections to
keep the chimney parts from twisting. Failure to do so
could cause fi re.

• Fasten offset/returns to chimney sections. Insert the

screws (provided) through the predrilled holes. Do NOT
penetrate inner fl ue.

• Secure chimney returns with hanger straps provided;

fasten to studs or joists.

• Vertical straight runs of chimney must be supported every

35 ft (10.7 m).

C. Assemble Chimney Sections

WARNING! Risk of Fire! DO NOT install substitute or
damaged chimney components.
• Use only those components described in this manual.
Substitute or damaged chimney components could impair
safe operation and cause overheating and fi re.

D. Install Chimney Air Kit

• Required in Canada.
• Follow instructions provided with this accessory.

• Install a ceiling fi restop whenever chimney penetrates

ceiling/fl oor.

• Mark and cut an opening in ceiling as shown in

Figure 8.5.

• Frame the opening with the same size lumber used in

the ceiling joists.

• Nail the ceiling fi restop to the bottom of the ceiling joists

when there is a room above.

• Use an attic insulation shield if the ceiling is insulated.

The ceiling fi restop may then be attached above or below
the joists.

E. Install Ceiling Firestops

CAUTION! Risk of Fire! Ceiling fi restops must be used
whenever the chimney penetrates a ceiling/fl oor.

• Chase construction requires ceiling fi restops at each

fl oor or every 10 ft (3.05 m) of clear space.

• The

ceiling

fi restop slows spread of fi re and reduces cold

air infi ltration.

WARNING! Risk of Fire! DO NOT seal area between
fi restop opening and chimney pipe except where they
enter the attic or leave the warm air envelope of the
home (use 600° F sealant).

Heatilator • SC60 • 32838 Rev X • 10/08

Catalog #

A

B

Angle

in.

mm

in.

mm

FS338

14-1/2

368

14-1/2

368

FS339

14-1/2

368

18-3/8

467

15°

FS340

14-1/2

368

23

584

30°

Advertising