Specifications 88

Specifications

Environmental specifications

Specification

Value

Temperature

Operating

1

10°C to 35°C (50°F to 90°F)

Non-operating

30°C to 60°C (-22°F to 140°F)

Maximum rate of temperature
change

Operating

2,3

10°C/hr (18°F/hr)

Non-operating

20°C/hr (36°F/hr)

Relative humidity
(noncondensing)

Operating

10% to 90%

Non-operating

5% to 95%

Maximum wet bulb
temperature (non-condensing)

Operating

28°C (82.4°F)

Non-operating

38.7°C (101.7°F)

Altitude

Operating

2

3,050 m (10,000 ft)

Non-operating

9144 m (30,000 ft)

Maximum rate of altitude
change

Operating

457 m/min (1,500 ft/min)

Non-operating

457 m/min (1,500 ft/min)

1

All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048

m (10,000 ft) is applicable. No direct sunlight allowed.

2

The type and number of options installed can limit the upper limit.

3

System performance may be reduced if operating with a fan fault above 30ºC (86ºF).

Mechanical specifications

Specification

Value

Dimensions

Height

4.32 cm (1.69 in)

Depth

70.00 cm (27.56 in)

Width

44.81 cm (17.64 in)