SECTION 3 − INTRODUCTION

3-1. Specifications

Max. Open

Circuit

Amps Input at Rated Output, 60 Hz, Single-Phase

Rated Output

Circuit

Voltage

200 V

230 V

KVA

KW

150 A at 23 VDC,

40% Duty Cycle

33

29

2.3*

25

2*

5.8

0.4*

4.9

0.1*

Wire Type and Diameter

No Load Wire Feed

Speed

Dimensions

Weight

Solid Steel/

Stainless Steel

Aluminum

Flux Cored

90−750 IPM

(2.3−19 m/min)

H: 31-1/4 in (794

mm)

W: 18-7/8 in (479

146 lb

(66 kg)

.023 − .045 in

(0.6 − 1.2 mm)

.030 − .035 in

(0.8 − 0.9 mm)

.030 − .045 in

(0.8 − 1.2 mm)

W: 18 7/8 in (479

mm)

D: 36-1/2 in (927

mm)

* While idling

3-2. Welding Power Source Duty Cycle And Overheating

Duty Cycle is percentage of 10 min-

utes that unit can weld at rated load

without overheating.
If unit overheats, thermostat(s)

opens, output stops, and cooling

fan runs. Wait fifteen minutes for

unit to cool. Reduce amperage or

voltage, or duty cycle before

welding.
Y Exceeding duty cycle can

damage unit and void

warranty.

Overheating

0

15

A or V

OR

Reduce Duty Cycle

Minutes

duty1 4/95 − 199 211

4 Minutes Welding

6 Minutes Resting

40%dutycycle