11. changing input voltage – Hobart Welding Products IRONMAN M-10 User Manual

Page 19

Advertising
background image

OM-927 Page 15

3-10. Installing Wire Spool And Adjusting Hub Tension

When a slight force is needed

to turn spool, tension is set.

15/16 in

Use compression spring

with 8 in (200 mm) spools.

Tools Needed:

072573-B / 802 922

Installing 1 Or 2 lb Wire Spool

To install either a 1 lb or 2 lb wire

spool, follow the procedure as

shown in the illustration.

Remove these

components

from spindle.

Spindle

Spindle

Install these

components

onto spindle.

Order extra spring

Part No. 186 437

3-11. Changing Input Voltage

801 580-A

Y Turn Off unit, and disconnect

input power.

Unit was shipped from factory set

for 230 volts.
1

Transformer T1

2

Rear Of Power Switch S1

3

Lead Marked 230 Volt And

Fan Motor Lead

Disconnect 230 volt lead and fan

motor lead from rear of S1. Leave

fan motor lead connected to 230

volt lead.
4

Lead Marked 200 Volt

Remove cable tie, and slide short

piece of sleeving off 200 volt lead,

and slide sleeving over end of 230

volt and fan motor leads. Fold

sleeving over and secure in place.
Connect 200 volt lead to S1 where

230 volt lead was removed.
Reinstall wrapper.

3/8, 7/16 in

1

Tools Needed:

4

2

3

Advertising