Maintenance – Husqvarna 18 ProFlex User Manual

Page 35

Advertising
background image

English –

33

MAINTENANCE

Replacing the cutting unit’s belts

Belt replacement on the BioClip unit

Two transmission belts that synchronise the rota-
tion of the blades power a BioClip unit. The belts
are located under a hood on the cutting unit.

1. Loosen the parallelism arm’s front pin/bolt and

fold the arm backwards.

2. Loosen the two bolts holding the protective

hood and then lift off the hood.

Loosen the nuts on the eccentric plate and turn
this away.

Loosen the four nuts (see diagram) holding the
outer blade bearing enough so that the bearing
can be moved.

Slide the blade bearing in towards the centre
bearing and pry off the upper belt.

Repeat the procedure for the lower belt.

!

3.

WARNING!

Protect your hands by wearing gloves
when working with the blades.

Advertising
This manual is related to the following products: