Installation

311053C

7

Mount Gun

Reciprocating Arm Rod Mount

Manifolds 241161 and 241162

To mount the gun on a reciprocating arm rod [0.5 in. (13
mm) diameter maximum]:

1.

Insert the mounting bar (A) through the hole in the
manifold as shown in F

IG

. 3.

2.

Secure the gun to the bar by tightening the mount-
ing screw (B).

3.

Ensure the tip of the gun is 8 to 10 in. (150 to 200
mm) from the surface of the object being sprayed.

Stationary Support Mount

All Manifolds

To mount the gun on a stationary support (refer to F

IG

.

4. and Mounting Hole Layout, page 28):

1.

Attach the gun to the support with two M5 x 0.8 cap-
screws (C). The screws must be long enough to
engage the threaded holes in the gun manifold to a
depth of 1/4 in. (6 mm).

2.

Ensure the tip of the gun is 8 to 10 in. (150 to 200
mm) from the surface of the object being sprayed.

Use the 1/8 in. alignment pin (P) to assist in
orienting the gun.

F

IG

. 3: Reciprocating Arm Mount

TI8111a

A

B

P

F

IG

. 4: Stationary Support Mount

C

TI8112a