2-18

Connecting Fixtures

Studio Color LCD Controller

Because each fixture has a unique fixture number, each one
responds to commands from the controller independently
from the other fixtures.

Since fewer than 32 Studio Color fixtures are attached to the
controller and because no cable spans more than 500 ft. (153
m), a serial data distributor is not required.

Example #2: Multiple controllers are linked together as
masters and slaves. One link spans more than 500 ft (153 m).

Figure 2-13. This example shows three controllers
interconnected via their Master and Slave ports.
The master controller provides a single point of
playback control.

In the example above, three Studio Color LCD controllers are
connected to multiple fixtures. The first controller is
designated as the master controller by setting switch B-1 to
OFF. The other two controllers are slaves (switch B-1 set to
ON). Only one master controller is allowed per link.

The master controller controls playback of programs that
have already been created on the slaves. (You program the
slave controllers independently, then play back the programs
from the master controller.) The master controller can also

XLR data cabling

Master Controller

Slave Controller

Stereo cabling

Serial Data
Distributor

In

Out Out Out Out Out

Long distance

To more fixtures

To more fixtures

Master port

Master port

Slave port

Slave Controller

To more fixtures

Fixture #1

Fixture #2

Fixture #3

Fixture #5

Fixture #4

Fixture #2

Fixture #4

Fixture #1

Fixture #2

Stu

dio

Col

or

Stu

dio

Col

or

Stu

dio

Col

or

Stu

dio

Col

or

Stu

dio

Col

or

Stu

dio

Col

or

Stu

dio

Col

or

Stu

dio

Col

or

Stu

dio

Col

or

Advertising