2. routine maintenance (kohler-powered units) – Hobart Welding Products CHAMPION ELITE OM-240 438B User Manual
Page 43
.
A complete Parts List is available at www.HobartWelders.com
OM-240 438 Page 39
9-2. Routine Maintenance (Kohler-Powered Units)
!
Stop engine before maintaining.
.
See Engine Manual and Maintenance Label
for important start-up, service, and storage
information. Service engine more often if
used in severe conditions.
Recycle engine
fluids.
n = Check
Z = Change
~ = Clean
l = Replace
* To be done by Factory Authorized Service Agent
Reference
Every
8
Hours
n Fuel Level
n Oil Level
~ Oil, Fuel Spills
Every
20
Hours
n~ Spark Arrestor Screen
Every
25
Hours
~ Air Cleaner Wrapper
Every
50
Hours
~ Weld Terminals
Every
100
Hours
Engine
Manual,
~ Battery Terminals
~ Cooling System
Z Oil
nl Air Cleaner Element
Every
200
Hours
Engine
Manual,
l Unreadable Labels
n Spark Plug Gap
Z Oil Filter
l Fuel Filter
Every
500
Hours
Engine
Manual
nl Weld Cables
n~ Slip Rings*
nl Brushes*