9-2. Routine Maintenance (Kohler-Powered Units)

!

Stop engine before maintaining.

.

See Engine Manual and Maintenance Label
for important start-up, service, and storage

information. Service engine more often if

used in severe conditions.

Recycle engine

fluids.

n = Check

Z = Change

~ = Clean

l = Replace

* To be done by Factory Authorized Service Agent

Reference

Every

8

Hours

Section 5-5

n Fuel Level

n Oil Level

~ Oil, Fuel Spills

Every

20

Hours

Section 9-7

n~ Spark Arrestor Screen

Every

25

Hours

Section 9-3

~ Air Cleaner Wrapper

Every

50

Hours

~ Weld Terminals

Every

100

Hours

Engine

Manual,

Section 9-3,

9-4

~ Battery Terminals

~ Cooling System

Z Oil

nl Air Cleaner Element

Every

200

Hours

Engine

Manual,

Section 9-4

l Unreadable Labels

n Spark Plug Gap

Z Oil Filter

l Fuel Filter

Every

500

Hours

Engine

Manual

nl Weld Cables

n~ Slip Rings*

nl Brushes*