30 –

English

Maintenance

8

Lift of the drive belt. Then pull out the pin.

9

Pull the frame forwards and refit the pin.

10 Grasp the front edge of the cutting unit, pull out and raise

into the service position.

If the cylindrical bolt, which is now holding the cutting unit is
removed, the cutting unit can be lifted off.

Restoring from service position

To leave the service position, reverse the procedures set out
in Placing in the service position. Make sure that the cutting
unit’s ”lug” (3) enters the loop correctly on the underside of the
machine, see diagram.

Checking the blades

To achieve the best mowing results it is important that the
blades are undamaged and well-sharpened.

Check that the blades’ attachment screws are tight.

The blades should be balanced after sharpening.

Damaged blades should be replaced when hitting obstacles
that result in a breakdown. Let the servicing dealer judge
whether the blade can be repaired/ground or must be
discarded.

Removing the BioClip plug

To change a Combi unit from BioClip function to cutting unit
with rear ejection, remove the BioClip plug located under the
unit with three screws.

1

Put the unit in the service position, see Placing in the
service position.

2

Remove the three screws holding the BioClip plug, and
remove the plug.

3

Tip: Fit three full-thread screws M8x15 mm in the screw
holes to protect the threads.

4

Replace the unit in normal position.

Fit the BioClip plug in the reverse order.

IMPORTANT INFORMATION Replacing or sharpening the
blades should be conducted by an authorised service
workshop.

Advertising