Cooling System (CT8775C Only)

CAUTION

Equipment Damage Hazard.

Can cause permanent damage to compressor or other equipment.

Do not operate cooling when outside temperature is below 50°F (10°C).

Allow compressor to remain off for five minutes before restarting.

See equipment manufacturer instructions.

❑

Slide the system switch to Cool and the Fan switch to Auto.

❑

Turn the dial counterclockwise to lower the temperature setting several degrees below the room temperature.

NOTE:

If a call for cooling is made before the compressor has been off for five minutes, or if a power interruption
occurs while the compressor is running, the thermostat will go into a five-minute delay to protect the com-
pressor. The snowflake

will flash during this delay.

❑

After five minutes, the thermostat will display a solid snowflake

to indicate the thermostat has called for cooling.

The cooling system should turn on.

❑

Turn the dial clockwise to raise the temperature setting above the room temperature.

❑

The snowflake

will disappear from the display to indicate the thermostat has ended the call for cooling. The

cooling system should turn off.

Fan (CT8775C Only)

❑

Slide the system switch to Off and the fan switch to On. The fan should run continuously.

❑

Slide the Fan switch to Auto. The fan should turn off.