Step 7. wire wallplate terminals – Honeywell CT8775A User Manual

Page 8

Advertising
background image

69-1676—1

8

STEP 7. WIRE WALLPLATE TERMINALS

IMPORTANT

All wiring must comply with local codes and ordinances. If
unsure about household wiring procedures, call your local
heating/air conditioning contractor.

❑

Refer to the labels you placed on the wires when you removed the
old thermostat (see illustration).

❑

Match the letter of your old thermostat wire with the corresponding
terminal letter on your new thermostat. Refer to Table 2.

IMPORTANT

Remove the factory-installed jumper connecting terminals R
and Rc on the CT8775C Thermostat if wires will be con-
nected to both of these terminals.

❑

For wiring diagrams, see pp 16-17.

❑

Loosen the terminal screws. Slip each wire beneath its matching
terminal. Wraparound and straight connections are both acceptable,
(see illustration). Tighten the terminals.

❑

Plug the hole in the wall with insulation to help prevent drafts from
adversely affecting thermostat operation.

M19495

FACTORY

INSTALLED JUMPER

Y

G

R

W

M19496

FOR WRAPAROUND

INSERTION STRIP

7/16 IN. (11 MM).

FOR STRAIGHT INSERTION

STRIP 5/16 IN. (8 MM).

Advertising