C. clearances – Heatiator Heatilator Evolution NEVO4236I NEVO3630I User Manual

Page 20

Advertising
background image

Heatilator • Evolution • 4065-114 Rev. o • 11/11

20

D

Clearance to Ceiling

30 in. (762 mm)

0 in.

0 in. TO LEVEL

OF STANDOFFS

Combustible Object

36 in.

(914 mm)

0 in.

Combustible flooring may be installed next
to the front of the appliance.

Drywall

1/2 in.

(13 mm)

1/2 in.

(13 mm)

C

A

B

Figure 5.2

Clearances to Combustibles

C. Clearances

NOTICE:

Install appliance on hard metal or wood surfaces

extending full width and depth. DO NOT install directly on
carpeting, vinyl, tile or any combustible material other than
wood.

WARNING! Risk of Fire!

Maintain specifi ed air space

clearances to appliance and vent pipe:

Note: If the inside of the framed cavity is to be
fi nished, the framing dimensions must include the
fi nished surface. If drywall is to be attached to the
rear wall, the depth must be measured from the
drywall surface.

• Insulation and other materials must be secured to

prevent accidental contact.

• The chase must be properly blocked to prevent blown

insulation or other combustibles from entering and
making contact with fi replace or chimney.

Failure to maintain airspace may cause overheating and
a fi re.

Model

A

Rough Opening

(Width)

B

Rough Opening

(Height)

C

Rough Opening

(Depth)

D

Rough Opening

(DVP Pipe)

D

Rough Opening

(SLP Pipe)

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

NEVO3630

36

914

39 7/8

1013

19 5/8

498

10

254

9

229

NEVO4236

42

1067

39 7/8

1013

19 5/8

498

10

254

9

229

If using the optional fi nishing trim, the unit must be installed on a platform at least 1 1/2 in.
high. The rough opening height must be increased the same amount as the height of the
platform.