B. Vent Components Diagrams (continued)

Figure 17.9 Vent Components

SLP-TRAP

Horizontal Termination Cap

15-1/8 in.

(384 mm)

12 in.

(305 mm)

8 in.

(203 mm)

Max

Effective

Length

Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick.
If wall thickness is less than 4 in. (102 mm) the
existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B
will be required.

Heat

Shield

Term Cap

Minimum

Effective Length

Maximum

Effective Length

Trap1

3 1/8 in.

4 3/4 in.

79 mm

121 mm

Trap2

5 1/4 in.

9 1/4 in.

133 mm

235 mm

Optional Wire Harness

DESCRIPTION

PART NUMBER

10 ft. PV Wire Harness

PVI-WH10

20 ft. PV Wire Harness

PVI-WH20

40 ft. PV Wire Harness

PVI-WH40

60 ft. PV Wire Harness

PVI-WH60

80 ft. PV Wire Harness

PVI-WH80

100 ft. PV Wire Harness

PVI-WH100

PVI-SLP

Power Vent Inline

SLP-LPC

SLP Low Profi le Cap

Note: Wire harnesses required to power the PVI-SLP
connect to the appliance and are ordered separately
from PVI-SLP. Contact your dealer to order.

16 IN.

406 mm

15 IN.

(381 mm)

16-11/16 IN.

(424 mm)

9-3/16 IN.
(233 mm)

4-1/2 IN.

114 mm

16-11/16 IN.

424 mm

13-5/8
(346 mm)

12-1/2 IN.
(318 mm)

12-1/2 IN.
318 mm

20-3/4 IN.
527 mm

13-5/8 IN.
346 mm

EFFECTIVE LENGTH
32 IN. (813 mm) MIN.
35 IN. (889 mm) MAX.