C. install the ceiling firestop – Heatiator Heatilator Evolution NEVO4236I NEVO3630I User Manual

Page 36

Advertising
background image

Heatilator • Evolution • 4065-114 Rev. o • 11/11

36

3 fasteners

per side

Ceiling firestop

installed below ceiling.

Ceiling firestop

installed above ceiling.

Install attic insula-
tion shields before
or after installation
of vent system.

ATTIC ABOVE

A

PIPE

DVP

SLP

A

10 in. (254 mm)

9 in. (229 mm)

A

C. Install the Ceiling Firestop

A ceiling fi restop MUST be used between
fl oors and attics.

DVP pipe only - Frame an opening 10 in.

by 10 in. (254 mm by 254 mm) whenever
the vent penetrates a ceiling/fl oor (see
Figure 8.3).

SLP pipe only - Frame opening 9 in. x

9 in. (229 mm x 229 mm) whenever the
vent penetrates a ceiling/floor (see Figure
8.3).

Frame the area with the same sized lumber
as used in ceiling/fl oor joist.

• The

ceiling

fi restop may be installed above

or below the ceiling joists when installed
with a attic insulation shield. It must be
under joists between fl oors that are not
insulated. Refer to Figure 8.4.

• Secure with three fasteners on each side.

Figure 8.3

Installing Ceiling Firestop

Figure 8.4 Installing the Attic Shield

WARNING! Risk of Fire!

DO NOT pack insu-

lation around the vent. Insulation must be kept
back from the pipe to prevent overheating.