Venting – Harman PP38+ User Manual

Page 10

Advertising
background image

10

PP38+ Pellet Stove

3-90-08422R33_06/13

#2 Preferred method

This method also provides excellent venting for normal

operation but requires the stove to be installed farther from

the wall. The vertical portion of the vent should be three to

five feet high and at least three inches from a combustible

wall. This vertical section will provide natural draft in the event

of a power failure.
If the stove is installed below grade be sure the vent

termination is at least 18" above grade. The outlet must also

be 1 foot from the house/building.
Note: Do not place joints within wall pass-throughs.

#1 Preferred method

This method provides excellent venting for normal operation

and allows the stove to be installed closest to the wall. Two

inches from the wall is safe; however, four inches allows

better access to remove the rear panel. The vertical portion of

the vent should be three to five feet high. This vertical section

will help provide natural draft in the event of a power failure.
note: do not place joints within wall pass-throughs.

venting

12" min. wall to outlet

caution

Keep combustible materials (such as grass, leaves,

etc.) at least 3 feet away from the flue outlet on the

outside of the building.

Fig. 8

3 ft.

to

combustibles

3 ft.

to combustibles

Fig. 9

3 ft.

to

combustibles

3 ft.

to combustibles

36" min clearance to any

combustible material