Venting, 8 installing through the ceiling – Harman PP38+ User Manual
Page 13
13
PP38+ Pellet Stove
3-90-08422R33_06/13
#8 installing through the ceiling
Through the ceiling vent, follow PL vent manufacturers
recommendations when using wall and ceiling pass through.
note: do not place joints within wall pass-throughs.
Fig. 14
PL vent manufacturer's
firestop spacer and support
(See Page 7 for
corner installation
clearances)
Minimum flue vent configuration
It is required that outside air
be installed with this venting
configuration to reduce smoke and
creosote smell in the room in the
event of power failure.
Min. above ground level
12"
Storm collar
Flashing
3" min.
3" min.
12" min.
3" min.
venting
Fig. 15
3" min.
No insulation or
other combustible
materials are allowed
within 3" of the pellet
vent pipe. Unless
specified by the pipe
manufacturer
Fig. 16
12"
min. wall to outlet
36"
min. clear
anc
e to an
y
combustable ma
terial