Venting – Harman PP38+ User Manual

Page 11

Advertising
background image

11

PP38+ Pellet Stove

3-90-08422R33_06/13

#4 installing into an existing chimney

This method provides excellent venting for normal operation.

This method also provides natural draft in the event of a

power failure. If the chimney condition is questionable* you

may want to install a liner as in method #7.
In some places in the US and Canada it is required that the

vent pipe extend all the way to the top of the chimney.
*The chimney should be inspected and cleaned before

installing your stove. If you discover that the chimney does

not have a clay tile liner or has cracks or flaking of the tile

liner you will need to install a stainless steel liner within

the chimney. In most cases the inside diameter of this liner

should be 4". Either flexible or rigid liner may be used for

this purpose. Refer to Method 6 & 7.
Be sure to design the venting so that it can be easily cleaned.

#5 Installing into an existing fireplace chimney

This method provides excellent venting for normal operation.

This method also provides natural draft in the event of a

power failure. If the chimney condition is questionable* you

may want to install a liner as in method #6.
In some places in the US and Canada it is required that the

vent pipe extend all the way to the top of the chimney.
*The chimney should be inspected and cleaned before

installing your stove. If you discover that the chimney does

not have a clay tile liner or has cracks or flaking of the tile

liner you will need to install a stainless steel liner within

the chimney. In most cases the inside diameter of this liner

should be 4". Either flexible or rigid liner may be used for

this purpose. Refer to Method 6 & 7.
The chimney should be sealed at the damper using a

steel plate. Kaowool, mineral wool or an equivalent non-

combustible insulation is recommended to be installed on top

of the sealing plate to reduce the possibility of condensation.

The connector pipe should extend through the smoke

chamber to the base or into the first flue tile.
Be sure to design the venting so that it can be easily cleaned.

Fig. 10

Fig. 11

venting