Draft test procedure – Harman PP38+ User Manual

Page 18

Advertising
background image

18

PP38+ Pellet Stove

3-90-08422R33_06/13

A simple draft test should be performed before and after

completing the flue pipe installation. To compare and to record

the results for future reference:
1. Plug the unit into a 120 VAC, 60 HZ outlet.
2. Close the hopper lid, front view door, and the ash pan.

Neither pellets or a fire are required for this test.

3. With the mode selector in the "OFF" position, turn the feed

adjuster to "TEST".

4. Record the high draft______in W.C. (Normal is -.50 to

-.60) The control will be on the High Draft for a minute.

5. After 1 minute, the combustion motor will go down to low

draft and the distribution blower will go on high. Allow

approximately 15 seconds to pass for the combustion

motor to slow before checking the low draft.

6. If the low draft is between -.25 and -.35, record the reading

_____ in W.C.

If the reading is lower, check for resistance in the venting

configuration. Too many elbows, or excessive horizontal runs

will add resistance. Also, be sure the doors and hopper lid

are properly secured.
As long as the draft reading drops when the combustion

blower goes to low speed, higher readings are not an issue.

Long vertical runs can actually increase the readings due to

the addition of natural draft. If the draft reading does not drop,

there is likely restriction on the air intake. Be sure the intake

flapper is opening and check for resistance in the outside air

conduit if installed.

draft test Procedure

Fig. 23

Draft Meter bolt hole

location

On a PP38 the draft test hole

is under the left rear corner

of the firebox.

Advertising