Installing wall mount dispensers – Follett 25 User Manual

Page 11

Advertising
background image

Installing wall mount dispensers

1. Install supplied wall bracket with six 3/8" diameter fasteners as shown in Fig. 7.

Note: Three holes are available at each fastening site to allow capture of studs/support within wall.

Steps 2 - 3 are required for models with integral icemaker only (25HT400A/W and 50HT400A/W).

2. For models with integral icemaker, use straight edge to position filler strip flush with top edge of wall bracket.

3. Fasten filler strip to wall as shown in Fig. 8.

4. For all models, cut utility hole in wall (Figs. 7 and 8) using wall bracket as template.

5. Lift dispenser onto wall bracket, positioning unit so that hook on back of dispenser is captured by wall bracket

support angle (Fig. 6, hook detail).

6. Install four 1/4-20 screws through bottom of wall bracket into bottom of dispenser to secure dispenser to bracket.

7. Remove splash panel. Water line to solenoid valve can be disconnected from water inlet valve by pushing on ring

at end of inlet fitting while pulling on tubing.

13.5"

(343mm)

18"

(457mm)

23"

(584mm)

16.875"

(429mm)

18.5"

(470mm)

21.5"

(546mm)

2.5"

(64mm)

17.125"

(435mm)

24"

(610mm)

25HT400A/W

12" (305mm)

50HT400A/W

16" (406mm) 25HT400A/W

44" (1118mm)

50HT400A/W

48" (1219mm)

support angle and

hook detail

Fig. 6 – Side view and angle detail for wall mount units without drain pan with integral icemaker
(in top of cabinet).
Wall mount units with Satellite-fill icemakers will not require installation of a filler strip.

Do not rest dispenser weight on bottom front edge of wall bracket.

!

11

Advertising
This manual is related to the following products:

50