Installing countertop dispensers – Follett 25 User Manual

Page 9

Advertising
background image

Installing countertop dispensers

1. Position dispenser in desired location, mark

dispenser outline on counter and remove
dispenser.

2. Drill four 3/8" (5mm) holes in counter (Fig. 2) to

anchor dispenser to counter.

Follett countertop dispensers can have any

or all utilities run directly through counter or
out rear of dispenser. For dispensers with any
utilities exiting through counter, make counter
cut-out (Fig. 2)

3. If ice transport tube will exit out rear of dispenser,

remove ice transport tube knock-out (Fig. 5G)
from rear of dispenser.

Note: Utility connections can be accessed

through front of dispenser by removing stainless
steel splash panel, or by removing access panel
(Figs. 4, 5) on back of dispenser.

4. If any electric utilities or water line will be

connected through rear of dispenser, remove
utility knock-out (Figs. 4, 5F) from rear of
dispenser and install supplied protective grommet.

21" (533mm)
20.125" (511mm)

12.5"

(317mm)

16.5"

(419mm)

6.5"

(165mm)

.375 (10mm)

1.5" (38mm)

.44" (11mm)

10.5"

(267mm)

9" X 14"

(227mm x 356mm)

drain pan

cut-out

.375" holes

(9.52mm)

.5"

(127mm)

Fig. 3 – Top view, dispenser plumbing connections countertop

(G) 3/8" FPT water inlet

(drain location)

(K) alternate 3/4" dispenser

condenser water inlet

(H) 3/8" FPT

drain pan

(L) 3/4" FPT dispenser drain

condenser water outlet

(J) 3/8" FPT

Dispensers with top mount icemakers cannot be mounted on legs. They must be bolted to counter.
Use gloves when lifting icemaker to protect hands from sheet metal edges.

!

Fig. 2 – Counter cut-out, all models

9

Advertising
This manual is related to the following products:

50