Follett 25 User Manual

Page 24

Advertising
background image

Ice transport tube replacement

Models 25FB400A/W, 50FB400A/W, 25CR400A/W, 50CR400A/W

1. Remove top and rear access panel from dispenser (lower front panel in freestanding unit).

2. Disconnect existing ice tube from engaging pin on transport tube bracket in ice storage bin and pull down through

dispenser chase.

3. Disconnect opposite end of tube from icemaker.

4. Run end of new ice transport tube with 3/16" (5mm) hole through ice transport tube knockout (Fig. 5G) in back of

dispenser or through counter into bottom of dispenser, being careful to avoid any bends with less than 6" (153mm)
radius.

5. Insert tube in internal chase in rear inside corner of dispenser (left side as you face dispenser) and push up into

storage area.

6. Push the 3/16" (5mm) hole near end of tube into pin on ice tube bracket (see drawing below).

Steps 7-8 for units with Satellite-fill icemakers only

7. Install supplied insulation to run of transport tube required for your site, leaving approximately 2" (51mm) of tube

exposed at free end.

8. Check that insulated tube runs continuously from icemaker to dispenser with no dips.

All units

9. Slip supplied hose clamp onto tube and push tube onto exit port of evaporator.

Do not twist hose when securing to evaporator.

10. Fasten tube on port with hose clamp, being sure that clamp is positioned on evaporator side of nozzle flange.

11. Tighten clamp.

Correct installation of ice transport tube is critical to Satellite-fill icemaker performance. Replacement
ice transport tubes for Satellite-fill icemakers must be insulated and run continuously from icemaker t
o dispenser with no dips or bends with a radius of less than 6" (153mm).

!

engaging pin

3/16 (5mm) ice tube hole

ice hose mounting bracket

ice level control stat

ice tube

1"

(26mm)

A

A

1"
(26mm)

Section A – A

.3/16" (5mm)
dia. hole

Only use tubing supplied by Follett Corporation.

!

24

Advertising
This manual is related to the following products:

50