Generation ii technical reference – Frymaster LOV M3000 User Manual

Page 29

Advertising
background image

LOV

Generation II Technical Reference

28

Tech Mode

Tech mode allows technicians to reset all passwords set in Levels One and Two and change the time
at which the fryer calls for a fi lter pad change. The default is 25 hours.

1. Press and hold

and

simultaneously for TEN

TEN seconds until a third chirp is

heard and

CODE

CODE is displayed.

2. Enter

1650

1650.

3. The computer displays

TECH MODE

TECH MODE and changes to CLEAR PASS-

CLEAR PASS-

WORDS

WORDS.

4. Press the 9 (1) button to accept selection and clear the passwords.

5. The computer displays

CLEAR PASSWORDS

CLEAR PASSWORDS on the left and COM-

COM-

PLETE

PLETE on the right. This clears any passwords set up under levels one and
two.

6. Press the

button to toggle to

FILTER PAD TIME

FILTER PAD TIME on the left and 25

25 on

the right. (25 hours is the default time to change the pad.)

7. Press the

8

(2) button to accept changes and exit.

8. The computer displays

OFF

OFF. Continue below to enter the setup mode.

Fryer Setup Mode

Fryer Setup Mode is used to setup the time, date, date format, language, fryer
type, vat type, oil system type, and temperature scale in the fryer’s computer.
These settings are needed for the fryer to function properly and should only be
changed by a technician upon initial power up after installing a new computer or
after accessing from Level 1.

With the computer displaying

OFF

OFF:

1. Enter Level 1 programming mode by pressing the TEMP and INFO buttons
simultaneously until

LEVEL 1

LEVEL 1 is displayed. The computer displays ENTER

ENTER

CODE

CODE.

2. Enter

1234

1234.

The computer displays

level 1 program

level 1 program for three seconds changing to

Product selection

Product selection .

3. Press the a button once to scroll to

FRYER SETUP

FRYER SETUP.

Advertising