Generation ii technical reference – Frymaster LOV M3000 User Manual

Page 7

Advertising
background image

LOV

Generation II Technical Reference

6

Manual — Used to toggle between automatic
and manual fi ltration mode. The unit must be
in manual mode for the other MIB buttons
to operate.

Select — Used to scroll through the vats,
which are shown numerically in the LED.

Drain — Used to open and close the drain
valve of the vat indicated on the display.
When pressed an LED on the button indicates
activity: slow blink, awaiting response from
AIF; LED illuminated constantly, drain open;
no illumination, drain closed.

Return — Used to open and close the return
valve on the vat indicated on the display. It also
controls the pump. When pressed an LED on the
button indicates activity:

blink: awaiting response from AIF,
LED illuminated constantly: drain open,
no illumination: drain closed.



The pump operates with a momentary switch.
Pressing and holding the return button after
the valve is open activates the fi lter pump.
Releasing the button deactivates the pump.

The mode display on the face of the MIB board
displays a range of letters, which indicate
activity or an error. These codes are listed on
the next page.

The MIB board.

Mode Display
Shows status
(auto or manual)
vat number (when
operating valves
manuals) and dis-
plays error codes.

Manual/Auto
Switches fryer from
auto to manual
operation.

Reset
Resets system,
ensures all valves
are closed.

Drain
Opens and closes
drain valves in
manual mode.

Vat Selection
Selects vat for
manual operation of
valves.

Return
Opens and closes
return valves and
turns on fi lter
pump in manual
mode.

The MIB is mounted behind the left door. See arrow.