MIB (Manual Interface Board) Display Diagnostics

DISPLAY

LED

EXPLANATION

Drain

Vat # (The vat number is followed by an “L” to
indicate left side of a split vat or an “r” to indicate the
right side of a split vat or a full vat.)

On

Drain valve on vat # is open.

Vat # (The vat number is followed by an “L” to
indicate left side of a split vat or an “r” to indicate the
right side of a split vat or a full vat.)

Off

Drain valve on vat # is closed.

Vat # (The vat number is followed by an “L” to
indicate left side of a split vat or an “r” to indicate the
right side of a split vat or a full vat.)

Blink

Drain valve on vat # is opening or closing
or an error condition may exist.

Return

Vat # (The vat number is followed by an “L” to
indicate left side of a split vat or an “r” to indicate the
right side of a split vat or a full vat.)

On

Return valve on vat # is open.

Vat # (The vat number is followed by an “L” to
indicate left side of a split vat or an “r” to indicate the
right side of a split vat or a full vat.)

Off

Return valve on vat # is closed.

Vat # (The vat number is followed by an “L” to
indicate left side of a split vat or an “r” to indicate the
right side of a split vat or a full vat.)

Blink

Return valve on vat # is opening or
closing or an error condition may exist.

Network

N

Network error, displays for 10 seconds in
no communications are received from the
M3000 within 10 seconds after power on
or MIB reset.

Resetting

r

An “r” is displayed for ten seconds or
until communication is received from the
M3000 after a power on or MIB reset.

Miscellaneous

E alternating with vat # (The vat number is followed
by an “L” to indicate left side of a split vat or an “r” to
indicate the right side of a split vat or a full vat.)

Blink

The circuit has an issue. Ensure the
actuator is plugged in. Ensure the CAN
connections are all securely plugged into
the connectors.

Indicates the AIF temperature sensor did
not detect a full vat during fi ltration.

A

Manual
LED off

The system is in auto fi ltration mode.

Vat # (The vat number is followed by an “L” to
indicate left side of a split vat or an “r” to indicate the
right side of a split vat or a full vat.)

Manual
LED on

The system is in manual mode.

P

This will only be displayed in auto
fi ltration mode. Filter pan is improperly
seated. Any auto fi ltration messages
received at this time are ignored.

Advertising