LOV

Generation II Technical Reference

37

FILL VAT FROM BULK:

1. Hold down “fi lter” button until computer beeps twice.
2. Scroll down to “Fill Vat from Bulk” using the Info button.
3. Press

“9”.

4. “Fill Vat from Bulk? Yes/No” is displayed.
5. Press

“9”.

6. “Press and Hold Yes to Fill / Yes” is displayed.
7. Press and hold down “9” to fi ll pot to desired level.
8. “Filling” is displayed during fi ll.
9. Release button to stop fi lling.
10. “Continue Filling? Yes/No” is displayed.
11. Press “8” to exit.

FILL JUG FROM BULK:*

1. When “Orange” indicator light is on, the top-off jug is empty.
2. To

refi ll jug press and hold the orange reset button above the jug until the jug is full.

3. Release the button to stop fi lling.

*NOTE: The jug may not fi ll if any of the following are in progress:

If

FILTER NOW? YES/NO

FILTER NOW? YES/NO, CONFIRM YES/NO

CONFIRM YES/NO, or SKIM VAT

SKIM VAT is displayed, the fi ll jug

button is disabled until either a fi lter is complete or until no is chosen.

The system also checks these conditions. The following must be met before jug fi ll is allowed:

Solenoid closed –

• Orange fi ll button pressed longer than 3 seconds.

• Waste valve closed.

• FILTER NOW? YES/NO

FILTER NOW? YES/NO, CONFIRM YES/NO

CONFIRM YES/NO, or SKIM VAT

SKIM VAT cannot be

displayed.

• System power cycle (all boards – computers, MIB, AIF and ATO) after changing setup from

JIB to Bulk (use momentary reset).

• No fi ltration or other fi lter menu selection can be in process.

Other factors that may not allow fi ll jug from bulk –

• Defective solenoid.

• Defective switch.

• RTI pump issue.

• RTI relay stuck.

If using two fryer systems that are both attached to the RTI system, they may not be able to fi ll
both units at the same time if they have an RTI unit with a single head. Some RTI units have dual
heads which can fi ll simultaneously.