Generation ii technical reference, Filter error flow chart – Frymaster LOV M3000 User Manual

Page 32

Advertising
background image

LOV

Generation II Technical Reference

31

Filter Error Flow Chart

This chart follows the process of clearing a

Filter Error

Filter Error prompt. The prompt is displayed when any of the

following occur:

1. a clogged fi lter pad,
2. a tripped or defective fi lter pump,
3. a leaky O-ring on the pick up tube,
4. a clogged pressure switch (gas fryer),
5. a failed drain valve/actuator, or
6. a failed return valve/actuator.

It is cleared by following the prompts.

If the computer displays

SERVICE

SERVICE

REQUIRED

REQUIRED, the fryer can be used in most
cases by answering

NO

NO when the prompt

for

SYSTEM ERROR FIXED? YES

SYSTEM ERROR FIXED? YES

NO

NO is displayed. The message repeats every
15 minutes until the issue is repaired and
error cleared by a technician. To clear the
error, enter 1111 after answering

YES

YES when

SYSTEM ERROR FIXED? YES NO

SYSTEM ERROR FIXED? YES NO
is displayed.

Change filter pad and

ensure filter pan is

pulled out for a
minimum of 30

seconds.

Fryer returns to

cook mode for 4

minutes or 15

minutes if pad

change expired.

NORMAL

OPERATION

RESUMES

SIXTH

CONSECUTIVE

FILTER ERROR

Fryer returns to

cook mode for 15

minutes.

TECH

ENTERS

CODE

MESSAGE

DISPLAYED

Call an Authorized

Repair Technician

Advertising