Generation II Technical Reference

3

The ATO board is positioned under the LON gateway in a
box with a transformer that provides power to the board.
The LON gateway must be removed to access the ATO
board.

The reservoir, or JIB, rests behind the right
door of the fryer. A light on the front of the fryer
illuminates when the jug is empty.

Problem

Probable Causes

Corrective Action

Frypot tops off cold.

Incorrect setpoint.

Ensure setpoint is correct.

No power to ATO board.

A. J5 connection unplugged.

B. Fuse blown.

C. Transformer malfunction.

A. Check to ensure J5 on front of

ATO board is fully locked into
connector.

B. Ensure fuse below right control

box is not blown.

C. Check that proper voltage is

present at transformer. See
charts on pages 43-47.

The yellow JIB low light

won’t illuminate.

A. Loose wire connection.

B. Power in the component box is not

present.

C. Failed transformer.

A. Ensure the yellow LED is

securely attached to plug J6 on
the ATO board.

B. Ensure power is present in the

component box.

C. If power is present in component

box, check the transformer for
correct voltage.