John Wood SERIES 100 User Manual

Page 2

Advertising
background image

2

These designs comply with the current version of the Standard for Gas Water

Heaters, Volume III, ANSI Z21.10.3 / CSA 4.3 as automatic circulating tank water

heaters, and automatic storage water heaters.

Detailed installation diagrams are found in this manual. These diagrams will

serve to provide the installer with a reference for the materials and methods

of piping necessary. It is highly essential that all water, gas piping and wiring

be installed as shown on the diagrams.

Particular attention should be given to the installation of thermometers at the

locations indicated on the diagrams as these are necessary for checking the

proper functioning of the heater.

In addition to these instructions, the equipment shall be installed in
accordance with those installation regulations in force in the local area
where the installation is to be made. These shall be carefully followed
in all cases. Authorities having jurisdiction should be consulted before
installations are made.

In the absence of local codes, the installation must comply with the current
editions of the CAN/CSA-B149.1, the Natural Gas and Propane Installation
Code and CSA C22.1, the Canadian Electrical Code. All documents are
available from the Canadian Standards Association, 5060 Spectrum Way,
Mississauga, Ontario, Canada, L.

FOREWORD

MODELS (A)JWSH100150 THRU (A)JWSH100250 ROUGH-IN-DIMENSIONS

GAS VALVE PIPING

(A)JWSH100150, (A)JWSH100199, &

(A)JWSH100250

3/4" NPT

Table 1. RECOVERY CAPACITIES - NATURAL GAS / L.P.

Model

Input

BTU/Hr.

Gas

Usage

Approx.

Gallon

Capacity

TEMPERATURE RISE - DEGREES F - GALLONS PER HOUR

30

40

50

60

70

80

90

100

110

120

130

140

(A)JWSH100150 150,000

nat/lp

100

576

432

345

288

247

216

192

173

157

144

133

123

(A)JWSH100199 199,900

nat/lp

100

767

575

460

384

329

288

256

230

209

192

177

164

(A)JWSH100250 250,000

nat/lp

100

960

720

576

480

411

360

320

288

262

240

221

206

Model

Gas

kW-Hr

Liter

Usage

Approx.

Capacity

TEMPERATURE RISE - DEGREES C - LITERS PER HOUR

17

22

28

33

39

44

50

56

61

67

72

78

(A)JWSH100150

44

nat/lp

379

2179

1635

1308

1090

934

817

726

654

594

545

503

467

(A)JWSH100199

58

nat/lp

379

2904

2178

1743

1452

1245

1089

968

871

792

726

670

622

(A)JWSH100250

73

nat/lp

379

3632

2724

2179

1816

1557

1362

1211

1090

991

908

838

778

Recovery capacities are based on 95% thermal efficiency.