Ap-5 – Furuno FCV-30 User Manual

Page 101

Advertising
background image

APPENDIX

AP-5

ETR

File

Load user setting (1-3)

Save user setting (1-3)

Close

Disp

Mode

Display mode (HF single, LF single,

Dual freq

, HF zoom, LF zoom)

Zoom mode (Bottom lock,

Bottom zoom

, Marker zoom)

Screen layout (

Vertical

, Horizontal)

A-scope (OFF, ON)

Display item ETR display item (Color bar, Time marker, Mode indicator, V-VRM, H-VRM, Depth)

Window size (

Small

, Medium, Large)

Setting Echo image

Low/High freq.

Range (5m, 10m, 20m,

40m

, 80m, 150m, 300m, 1200m)

Shift (0-1200;

0m

)

Gain (0.0-10.0;

5.0

)

TVG level (0-9;

3

)

TVG distance (30-1000;

100m

)

STC(0-100;

0

)

TVG curve (10,

20

, 30, 40, Manual(User setting: 0-40;

20

))

Common

Range details

User settings

Range 1 (2-10;

5m

)

Range 2 (5-20;

10m

)

Range 3 (10-40;

20m

)

Range 4 (30-80;

40m

)

Range 5 (40-150;

80m

)

Range 6 (80-300;

150m

)

Range 7 (150-1200;

300m

)

Range 8 (300-1200;

1200m

)

Zoom range (2m, 5m, 10m, 20m, 40m)

Zoom range details

User settings

Range 1 (2-120;

2m

)

Range 2 (2-120;

5m

)

Range 3 (2-120;

10m

)

Range 4 (2-120;

20m

)

Range 5 (2-120;

40m

)

Clutter (0-16;

9

)

Picture advance (Stop, 1/8, 1/4, 1/2,

1/1

, 2/1, 4/1)

Noise limiter (

OFF

, NL1, NL2, NL3)

Echo smoothing (

OFF

, 1, 2, 3, 4)

Signal level (0-14;

0

)

Tx rate (0-20;

20

)

Ping setting (

Internal

, External)

Auto mode (

OFF

, Fishing, Cruising)

Target echo (

Standard,

Surface)

9

Advertising