Warning, 2 4.1.3 replacing fuses, 4 transducer – Furuno FCV-30 User Manual

Page 92

Advertising
background image

4. MAINTENANCE & TROUBLESHOOTING

4-2

4.1.3 Replacing

fuses

Fuses protect the processor unit and transceiver unit from overvoltage and internal fault. If a
fuse blows find the cause before replacing it. If it blows again after replacement, request
service.

WARNING

Use the proper fuse.

Use of a wrong fuse can result in damage
to the equipment or cause fire.

Unit

Location of

fuse

How to replace

Rating

Code No.

Processor unit

In fuse holder

Unscrew the fuse
holder (on rear
panel) and replace
fuse. Screw in fuse
holder

FGMB 5A
AC250V

000-148-280

Transceiver unit

In fuse holder

Open the power
switch cover at
bottom of unit.
Unscrew the fuse
holder and replace
fuse. Screw in fuse
holder

100 VAC:
FGMB 10A
250 VAC

200 VAC:
FGMB 5A
AC125V

100 VAC:
000-104-815


200 VAC:
000-148-280

4.1.4 Transducer

Remove marine life and growth from the transducer face, using a piece of wood. DO NOT
paint the transducer face. Handle the transducer carefully.