3. CHANGING SETTINGS

3-7

Depth/Distance: This function compensates for depth difference between the picture from
the downward beam and other that from other directions when the sonar beam is oriented
in a direction other than downward.
Depth: Compensation applied (range scale shows depth)
Distance: No compensation (range scale shows distance from transducer)

TX power:
Sets output power. The higher the number the greater the output power.

Simul. TX start Rng: Sets start range for simultaneous transmission. The setting range is
100-5000 m. Note however that simultaneous transmission is not available with the 5000 m
range.

3.5

Temp Dialog Box

The temp dialog box sets up temperature data (fed from temperature sensor). With
connection of a temperature sensor, temperature change over time can be plotted on a
graph.

1. Click System in the menu bar.
2. Click Temp.

Temp dialog box description

Temp input: Choose the data format of temperature data.

CIF: Temperature data fed from net sonde
NMEA: Temperature data fed from navigation equipment.


Temp adjust: An offset may be applied CIF temperature data to correct it.
Offset range: -20.0°C - +20.0°C, -4°F - +68°F