-15-

Control Panel

A. EMERGENCY

STOP

Button—Disconnects

power to all motors in the motor cabinet.

B. MAIN BLADE OFF Button—Stops the main

saw blade.

C. SCORING BLADE OFF Button—Stops the

scoring blade.

D. MAIN BLADE DOWN Key—Lowers the

height of the main saw blade.

E.

SCORING BLADE RIGHT Key—Moves the
scoring blade right for alignment purposes.

F.

SCORING BLADE DOWN Key—Lowers the
height of the scoring blade.

G.

C

Key—Clears typed entries in the display.

H. Keypad—Keys for inputting the desired

angle of the saw blade.

I.

Stop

Key—Stops the trunnion movement.

J.

Start

key—Starts trunnion movement after

an angle has been entered.

K. “

+

” Key—Manually increases the angle of

the saw blades in increments of 0.1˚.

A

N

M

L

K

I

J

B

H

G

C

D

E

F

O

P

Q

T

R

S

L.

-

” Key—Manually decreases the angle of

the saw blades in increments of 0.1˚.

M.

Set

Key—Used to set blade angles entered

into the keypad. Also, used for calibration.

N. Digital Display—Displays the current angle

of the saw blades.

O. SCORING BLADE UP Key—Raises the

height of the scoring blade.

P.

ARBOR RPM Display—Displays the current
RPM of the saw blades.

Q. SCORING BLADE LEFT Key—Moves the

scoring blade left for alignment purposes.

R. MAIN BLADE UP Key—Raises the height of

the main saw blade.

S.

SCORING BLADE ON Button—Starts the
scoring blade. Note—

The main saw blade

must be ON for the scoring blade to start.

T.

MAIN BLADE ON Button—Starts the main
saw blade.

Figure 8. Control panel close-up.