FUNCTION TESTS

Test Auxiliary Controls

22 Turn the key switch to ground control and shut

the engine off.

23 Pull out the red Emergency Stop button to the

ON

position.

24 Simultaneously hold the auxiliary power switch

on and activate each boom function toggle
switch.

Note: To conserve battery power, test each

function through a partial cycle.

Result: All boom functions should operate.

At the Platform Controls

Test Emergency Stop

25 Turn the key switch to platform control and

restart the engine.

26 Push in the platform red Emergency Stop button

to the

OFF

position.

Result: The engine should turn off and all

functions should not operate.

27 Pull out the red Emergency Stop button and

restart the engine.

Test the Hydraulic Oil Return Filter

28 Move the engine idle select switch to high idel

(rabbit symbol).

29 Locate and check the hydraulic filter condition

indicator.

Result: The filter should

be operating with the
plunger in the green
area.

30 Move the engine idle

select switch to foot
switch activated high
idle (rabbit and foot
switch symbol).

Test the Service Horn

31 Push the horn button.

Result: The service horn should sound.

Test the Foot Switch

32 Push in the platform Emergency Stop button to

the

OFF

position.

33 Pull out the Emergency Stop button to

the

ON

position but do not start the engine.

34 Press down the foot switch and attempt to start

engine by moving the start toggle switch to
either side.

Result: The engine should not start.

35 Do not press down the foot switch and restart

engine.

36 Move the lift/drive select switch to the lift

position (if equipped).

37 Do not press down the foot switch. Then test

each machine function.

Result: The machine functions should not

operate.