SAFETY RULES

Electrocution Hazards

This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.

Maintain safe distances from electrical power lines
and apparatus in accordance with applicable
governmental regulations and the following chart.

Voltage

Minimum Safe

Phase to Phase

Approach Distance

Feet Meters

0 to 300V

Avoid Contact

300V to 50KV

10

3.05

50KV to 200KV

15

4.60

200KV to 350KV

20

6.10

350KV to 500KV

25

7.62

500KV to 750KV

35

10.67

750KV to 1000KV

45

13.72

Allow for platform movement, electrical line sway or
sag and beware of strong or gusty winds.

Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.

Do not operate the machine during lightning or
storms.

Do not use the machine as a ground for welding.

Tip-over Hazards

Occupants and equipment shall not exceed the
maximum platform capacity.

Maximum platform capacity
S-85

500 lbs

227 kg

Maximum platform capacity
S-80 with 8 Ft Platform

500 lbs

227 kg

Maximum platform capacity
S-80 with 6 Ft Platform

600 lbs

272 kg

Maximum platform capacity
S-80 with 6 Ft Platform
with foam-filled tires and proper
counterweight configuration

750 lbs

340 kg

Maximum occupants

2