Control panel – Grizzly G0613/G0614 User Manual

Page 10

Advertising
background image

-8-

G0613/14 Swivel Mast Metal Cutting Bandsaw

Control Panel

A. ON/OFF Push Button Switch: When the

cover is open, it allows access to the normal-
operation ON/OFF pushbutton switch that is
used to start and stop the bandsaw.

B. EMERGENCY Stop and Anti-Start Lockout

Cover: When the cover is closed but not
latched shut, it serves as an easy-to-find
EMERGENCY STOP button with anti-start
lockout. If pushed in an emergency situation,
the cover pushes the OFF button and then
latches shut, preventing accidental machine
startup.

Note: Both bandsaws also have an auto-
matic shut-off (limit switch) that turns the saw

OFF at the completion of the cutting arc.

C. Circuit Breaker: Kills power in the event of

high current draw or motor overload.

D. Cutting Fluid Pump Switch: Turns the cut-

ting fluid pump

ON.

Figure 2. G0613 control panel.

C

E. ON Button: Turns the motor ON and starts

the bandsaw.

F. OFF Button: Turns the motor OFF and stops

the bandsaw.

G. Cutting Speed Switch: Changes the motor

speed between 1725 and 3450 RPM, giving
two cutting speeds of 170 and 341 FPM.

H. Cutting Fluid Pump Switch: Turns the cut-

ting fluid pump

ON.

I. EMERGENCY STOP/OFF Button: Kills

power to the system and turns the motor

OFF. Twist the button until it pops out to re-
energize the system.

E

F

G

Figure 3. G0614 control panel.

A

B

H

I

D

Advertising