Grizzly G0613/G0614 User Manual

Page 14

Advertising
background image

-12-

G0613/14 Swivel Mast Metal Cutting Bandsaw

SECTION 2: CIRCUIT REQUIREMENTS

110/220V Single-

Phase (G0613)

Amperage Draw

The Model G0613 features a 110/220V motor
that is prewired for 110V and draws the following
amps under maximum load:

Motor Draw at 220V .............................7.7 Amps
Motor Draw at 110V ........................... 15.4 Amps

Circuit Requirements

We recommend connecting your machine to a
dedicated and grounded circuit that is rated for
the amperage given below. Never replace a circuit
breaker on an existing circuit with one of higher
amperage without consulting a qualified electri-
cian to ensure compliance with wiring codes.

If

you are unsure about the wiring codes in your

area or you plan to connect your machine to a

shared circuit, consult a qualified electrician.

110V Circuit ...........................................20 Amps
220V Circuit ...........................................15 Amps

220V Connection

Rewire the motors according to the wiring con-
nection diagram on the inside cover of the motor
and pump junction boxes. Refer to

G0613 Single

Phase 220V Wiring Diagram on Page 46 for
general wiring details. Also use the following
220V plug for your machine on a dedicated circuit
(see

Figure 4):

220V Plug & Receptacle ..............................6-15

Extension Cords

Using extension cords may reduce the life of the
motor. Instead, place the machine near a power
source. If you must use an extension cord:

For 110V, use at least a 12 gauge cord that
does not exceed 50 feet in length.

For 220V, use at least a 14 gauge cord that
does not exceed 50 feet in length.

Ensure that the extension cord contains a
ground wire and plug pin.

The Model G0613 is prewired for 110V opera-

tion. If you plan to use your machine at

220V, you must rewire the motor and install

the conversion kit part number P0613264.

Refer to the wiring diagram and consult a

qualified electrician.

Electrocution or fire could

result if this machine is

not grounded correctly or

if your electrical configu-

ration does not comply

with local and state codes.

Ensure compliance by

checking with a qualified

electrician!

Figure 4. Recommended 220V 6-15

outlet and plug.