Rewiring to 440v – Grizzly G0493 User Manual

Page 19

Advertising
background image

Model g0493 (Mfg. since 7/10)

-17-

3. pull the fuse that is in the “220” slot and push

it into the “440” slot (see

figure 8).

4. remove the main motor overload relay

(

figure 9) and replace it with the overload

relay from the 440v conversion kit. turn the
dial on the main motor overload relay to 9a.

5. on the scoring motor overload relay, change

the dial setting to 2.6a.

6. open the motor cabinet door and remove the

motor wiring covers from the main motor and
the scoring motor (see

figure 10).

figure 8. Fuse installed at the 220v location.

Fuse

7. rewire the motors as shown on the diagrams

that are placed on the inside of the motor wir-
ing covers.

scoring

Motor

Main

Motor

figure 10. Motor locations.

the Model g0493 can be rewired for 440v opera-
tion. the necessary parts for this procedure can
be purchased by calling our customer service at
(800) 523-4777 and ordering part #p04510016.

this rewiring job must be inspected by a quali-
fied electrician before the saw is connected to the
power source. also, the motors can be accessed
easier for rewiring if the blade is moved to 0˚ (90˚
to table) before beginning.

to rewire the machine for 440v operation:

1. disConneCt saW FroM poWer!

2. open the electrical panel and locate the volt-

age transformer shown in

figure 7.

rewiring to 440v

figure 7. inside view of the control panel.

scoring Motor

overload relay

Main Motor

overload relay

voltage

transformer

electrical

access panel

figure 9. Motor overload relays.

Main Motor

overload relay

scoring Motor

overload relay

Advertising